.1.3,SNMPv2-SMI::org,,,,,,
.1.3.6,SNMPv2-SMI::dod,,,,,,
.1.3.6.1,SNMPv2-SMI::internet,,,,,,
.1.3.6.1.1,SNMPv2-SMI::directory,,,,,,
.1.3.6.1.2,SNMPv2-SMI::mgmt,,,,,,
.1.3.6.1.2.1,SNMPv2-SMI::mib-2,,,,,,
.1.3.6.1.2.1.10,SNMPv2-SMI::transmission,,,,,,
.1.3.6.1.3,SNMPv2-SMI::experimental,,,,,,
.1.3.6.1.4,SNMPv2-SMI::private,,,,,,
.1.3.6.1.4.1,SNMPv2-SMI::enterprises,,,,,,
.1.3.6.1.4.1.31034,SCHLEIFENBAUER-SMI::schleifenbauer,,,,,,The Structure of Management Information for the Schleifenbauer enterprise.  Copyright (c) 2015 by Schleifenbauer Products BV
.1.3.6.1.4.1.31034.2,SDEVICE-MIB::device0,,,,,,
.1.3.6.1.4.1.31034.2.3,SDEVICE-MIB::identification,,,,,,
.1.3.6.1.4.1.31034.2.3.1,SDEVICE-MIB::spdmVersion,Integer32,read-only,,current,,Data model version, currently 1.10
.1.3.6.1.4.1.31034.2.3.2,SDEVICE-MIB::firmwareVersion,Integer32,read-only,,current,,The units firmware revision number.
.1.3.6.1.4.1.31034.2.3.3,SDEVICE-MIB::buildNumber,OCTET,read-only,,current,,Date and time of latest build of the firmware.
.1.3.6.1.4.1.31034.2.3.4,SDEVICE-MIB::salesOrderNumber,OCTET,read-only,,current,,SP sales order number.
.1.3.6.1.4.1.31034.2.3.5,SDEVICE-MIB::productId,OCTET,read-only,,current,,SP product id.
.1.3.6.1.4.1.31034.2.3.6,SDEVICE-MIB::serialNumber,OCTET,read-only,,current,,SP serial number.
.1.3.6.1.4.1.31034.2.3.7,SDEVICE-MIB::hardwareAddress,OCTET,read-only,,current,,Hardware serial number; cannot be changed. Can be used as backup unit address. format as 3 unsigned ints separated by dashes: int - int - int
.1.3.6.1.4.1.31034.2.3.8,SDEVICE-MIB::macAddress,OCTET,read-only,,current,,The ethernet interfaces unique hardware address.
.1.3.6.1.4.1.31034.2.3.9,SDEVICE-MIB::unitAddress,Integer32,read-write,,current,,User defined address; this will be used for addressing the unit.
.1.3.6.1.4.1.31034.2.3.10,SDEVICE-MIB::deviceName,OCTET,read-write,,current,,User configurable device name or identifier.
.1.3.6.1.4.1.31034.2.3.11,SDEVICE-MIB::deviceLocation,OCTET,read-write,,current,,User configurable device location identifier.
.1.3.6.1.4.1.31034.2.3.12,SDEVICE-MIB::vanityTag,OCTET,read-write,,current,,Characters to be displayed as vanity tekst in display.
.1.3.6.1.4.1.31034.2.4,SDEVICE-MIB::configuration,,,,,,
.1.3.6.1.4.1.31034.2.4.1,SDEVICE-MIB::noPhases,Integer32,read-only,,current,,Either zero, one or three for no input metering, single or three phase system
.1.3.6.1.4.1.31034.2.4.2,SDEVICE-MIB::noOutletsTotal,Integer32,read-only,,current,,Total number of outlets, even hardwired without switch/measure modules.
.1.3.6.1.4.1.31034.2.4.3,SDEVICE-MIB::noSwitchedOutlets,Integer32,read-only,,current,,Number of switched outlets. If outlet numbering is non-contiguous: the highest outlet number.
.1.3.6.1.4.1.31034.2.4.4,SDEVICE-MIB::noMeasuredOutlets,Integer32,read-only,,current,,Number of measured outlets. If outlet numbering is non-contiguous: the highest outlet number.
.1.3.6.1.4.1.31034.2.4.5,SDEVICE-MIB::noSensors,Integer32,read-only,,current,,The number of external, digital environmental sensors: 0 for none, 1 to 16 depending on number of reported sensors
.1.3.6.1.4.1.31034.2.4.6,SDEVICE-MIB::maximumLoad,Integer32,read-only,,current,,Maximum rated load of device per phase, usually either 16 or 32 A.
.1.3.6.1.4.1.31034.2.5,SDEVICE-MIB::systemstatus,,,,,,
.1.3.6.1.4.1.31034.2.5.1,SDEVICE-MIB::deviceStatusCode,Integer32,read-only,,current,,Returns an internal status or error code. 0 = OK, 16 = watchdog timer caused reset, 128 = slave module was reset, 144 = both previous.
.1.3.6.1.4.1.31034.2.5.2,SDEVICE-MIB::temperatureAlert,Integer32,read-only,,current,,An alert has been raised due to temperature exceeding treshhold; 0= no alert; 1= internal unit temp, 2= external sensor.
.1.3.6.1.4.1.31034.2.5.3,SDEVICE-MIB::inputCurrentAlert,Integer32,read-only,,current,,An alert has been raised due to current exceeding treshhold; 0=no alert; 1-3 for input phase.
.1.3.6.1.4.1.31034.2.5.4,SDEVICE-MIB::outputCurrentAlert,Integer32,read-only,,current,,An alert has been raised due to current exceeding treshhold; 0=no alert; 1-48 for outlet.
.1.3.6.1.4.1.31034.2.5.5,SDEVICE-MIB::inputVoltageAlert,Integer32,read-only,,current,,An alert has been raised due to a voltage dip; 0=no alert; 1-3 for input phase.
.1.3.6.1.4.1.31034.2.5.6,SDEVICE-MIB::oCurrentDropAlert,Integer32,read-only,,current,,An alert has been raised due to the current of a measured outlet suddenly dropping to near zero, possibly indicating a blown fuse; 0=no alert; 1-48 for outlet.
.1.3.6.1.4.1.31034.2.5.7,SDEVICE-MIB::iCurrentDropAlert,Integer32,read-only,,current,,An alert has been raised due to the current of a measured input suddenly dropping to near zero, possibly indicating a blown fuse; 0=no alert; 1-3 for phase.
.1.3.6.1.4.1.31034.2.6,SDEVICE-MIB::reset,,,,,,
.1.3.6.1.4.1.31034.2.6.1,SDEVICE-MIB::rebootDevice,Integer32,read-write,,current,,Warm reboot/reset of device; note: this will have no effect on outlet status!
.1.3.6.1.4.1.31034.2.6.2,SDEVICE-MIB::resetAlerts,Integer32,read-write,,current,,Reset all alert signals.
.1.3.6.1.4.1.31034.2.6.3,SDEVICE-MIB::zeroInputKWhSubtotal,Integer32,read-write,,current,,Reset of input kWh subtotal counters to zero.
.1.3.6.1.4.1.31034.2.6.4,SDEVICE-MIB::zeroOutKWhSubtotal,Integer32,read-write,,current,,Reset of outlet kWh subtotal counter to zero.
.1.3.6.1.4.1.31034.2.6.5,SDEVICE-MIB::resetPeakValues,Integer32,read-write,,current,,Reset all peak values to zero, as well input as output metering, voltages dips, current peaks and temperatures.
.1.3.6.1.4.1.31034.2.7,SDEVICE-MIB::settings,,,,,,
.1.3.6.1.4.1.31034.2.7.1,SDEVICE-MIB::general,,,,,,
.1.3.6.1.4.1.31034.2.7.1.4,SDEVICE-MIB::peakDuration,Integer32,read-write,,current,,A current peak should last at least [stpkdr] MilliSeconds before an alert is raised; max about a minute.
.1.3.6.1.4.1.31034.2.7.1.5,SDEVICE-MIB::fixedOutletDelay,Integer32,read-write,,current,,Minimal delay between two successive relay switches in milliseconds. Minimal delay is 100 ms. Will always be respected!
.1.3.6.1.4.1.31034.2.7.1.6,SDEVICE-MIB::powerSaverMode,Integer32,read-write,,current,,Set backlight on time in seconds; 0 keeps display always on. Note that keeping the backlight on may decrease luminosity over time. Setting this to other values than 10, 60, 120 or 240 is incompatible with the gateway!
.1.3.6.1.4.1.31034.2.7.1.7,SDEVICE-MIB::outletPowerupMode,Integer32,read-write,,current,,Behaviour of outlet on power-up: 0=off; 1=same state as at power down; 2=same state, but delayed by individual delay timer.
.1.3.6.1.4.1.31034.2.7.1.8,SDEVICE-MIB::maximumTemperature,Integer32,read-write,,current,,An alert should be generated whenever the temperature of the first connected T sensor is above this value. Zero means disabled.
.1.3.6.1.4.1.31034.2.7.1.9,SDEVICE-MIB::displayOrientation,Integer32,read-write,,current,,0 no display; display off; 1 vertical, display on top; 2 vertical, upside down; 3 horizontal, display at left; 4 horizontal, display at right
.1.3.6.1.4.1.31034.2.7.1.10,SDEVICE-MIB::localAlertReset,Integer32,read-write,,current,,Allow alerts to be reset locally on device by pushing one of the buttons. [replaces dipDuration]
.1.3.6.1.4.1.31034.2.7.1.11,SDEVICE-MIB::currentDropDetection,Integer32,read-write,,current,,Enables the current drop detection function. 0 = always off (default), 1 = input (s) only, 2 = output(s) only, 3 = both inputs and outputs.
.1.3.6.1.4.1.31034.2.7.1.12,SDEVICE-MIB::wirelessDisplayPower,Integer32,read-write,,current,,Controls the transit power of the wireless display transciever (if installed). Set to zero to completely disable the module.
.1.3.6.1.4.1.31034.2.8,SDEVICE-MIB::inputmeasuresTable,,not-accessible,,current,,This table contains all measures related to the measured inputs of the DEVICE. Note: either 1 or 3 channels, depending on number of phases measured.
.1.3.6.1.4.1.31034.2.8.1,SDEVICE-MIB::inputmeasuresEntry,,not-accessible,channelIndex6,current,,The record containing the registers for the channel selected by channelIndex.
.1.3.6.1.4.1.31034.2.8.1.1,SDEVICE-MIB::channelIndex6,Integer32,not-accessible,,current,,The channel. Its value ranges between 1 and 48, depending on the number of channels, usually 1.
.1.3.6.1.4.1.31034.2.8.1.2,SDEVICE-MIB::kWhTotalI,Integer32,read-only,,current,,Either the only phase in a single phase measurement; or one of the three phases in a multiphase measurement.
.1.3.6.1.4.1.31034.2.8.1.3,SDEVICE-MIB::kWhSubtotalI,Integer32,read-only,,current,,kWh subtotal register of the only phase in a single phase measurement; or one of three phases in a multiphase measurement. Reset to zero with [rsimks].
.1.3.6.1.4.1.31034.2.8.1.4,SDEVICE-MIB::powerFactorI,Integer32,read-only,,current,,The effective power factor in percent.
.1.3.6.1.4.1.31034.2.8.1.5,SDEVICE-MIB::actualCurrentI,Integer32,read-only,,current,,Actual apparent, RMS current.
.1.3.6.1.4.1.31034.2.8.1.6,SDEVICE-MIB::peakCurrentI,Integer32,read-only,,current,,Peak apparent, RMS current; highest value since last reset of the alerts.
.1.3.6.1.4.1.31034.2.8.1.7,SDEVICE-MIB::actualVoltageI,Integer32,read-only,,current,,The actual voltage.
.1.3.6.1.4.1.31034.2.8.1.8,SDEVICE-MIB::minVoltageI,Integer32,read-only,,current,,RMS voltage dip; lowest value since reset of alerts.
.1.3.6.1.4.1.31034.2.8.1.9,SDEVICE-MIB::powerVAI,Integer32,read-only,,current,,Power value calculated, not in data model of device.
.1.3.6.1.4.1.31034.2.8.1.10,SDEVICE-MIB::powerWattI,Integer32,read-only,,current,,Power value calculated by the gateway, not in data model of device.
.1.3.6.1.4.1.31034.2.8.1.11,SDEVICE-MIB::maxInletAmps,Integer32,read-write,,current,,Maximum current per input phase in A; should last at least [stpkdr] MilliSeconds before triggering an alert.
.1.3.6.1.4.1.31034.2.8.1.12,SDEVICE-MIB::inputCTratio,Integer32,read-write,,current,,The multiplier to use in case of use of /5 current transformers. Defaults to 1.
.1.3.6.1.4.1.31034.2.8.1.13,SDEVICE-MIB::inputName,OCTET,read-write,,current,,User configurable naming of inputs or phases. Useful if channels are used to measure branches..
.1.3.6.1.4.1.31034.2.9,SDEVICE-MIB::outletsTable,,not-accessible,,current,,This table contains the customer specific settings, determining toutlestablehe behaviour of the DEVICE.
.1.3.6.1.4.1.31034.2.9.1,SDEVICE-MIB::outletsEntry,,not-accessible,channelIndex4,current,,The record containing the registers forthe channel selected by channelIndex.
.1.3.6.1.4.1.31034.2.9.1.1,SDEVICE-MIB::channelIndex4,Integer32,not-accessible,,current,,The channel. Its value ranges between 1 and 48, depending on the number of channels, usually 1.
.1.3.6.1.4.1.31034.2.9.1.2,SDEVICE-MIB::outletName,OCTET,read-only,,current,,User configurable naming of individual outlets. Useful to distinguish outlets based on customer or device name.
.1.3.6.1.4.1.31034.2.10,SDEVICE-MIB::outputmeasuresTable,,not-accessible,,current,,This table contains all measures related to the measured outputs of the DEVICE. Note: up to 48 channels, depending on number of measured outlets.
.1.3.6.1.4.1.31034.2.10.1,SDEVICE-MIB::outputmeasuresEntry,,not-accessible,channelIndex7,current,,The record containing the registers for the channel selected by channelIndex.
.1.3.6.1.4.1.31034.2.10.1.1,SDEVICE-MIB::channelIndex7,Integer32,not-accessible,,current,,The channel. Its value ranges between 1 and 48, depending on the number of channels, usually 1.
.1.3.6.1.4.1.31034.2.10.1.2,SDEVICE-MIB::kWhTotalO,Integer32,read-only,,current,,Total kWh of selected output.
.1.3.6.1.4.1.31034.2.10.1.3,SDEVICE-MIB::kWhSubtotalO,Integer32,read-only,,current,,kWh subtotal register of selected output. Reset to zero with [rsomks].
.1.3.6.1.4.1.31034.2.10.1.4,SDEVICE-MIB::powerFactorO,Integer32,read-only,,current,,Power factor of output.
.1.3.6.1.4.1.31034.2.10.1.5,SDEVICE-MIB::actualCurrentO,Integer32,read-only,,current,,Actual apparent, RMS current.
.1.3.6.1.4.1.31034.2.10.1.6,SDEVICE-MIB::peakCurrentO,Integer32,read-only,,current,,Peak apparent, RMS current; highest value since last reset of alerts.
.1.3.6.1.4.1.31034.2.10.1.7,SDEVICE-MIB::actualVoltageO,Integer32,read-only,,current,,Actual voltage on output.
.1.3.6.1.4.1.31034.2.10.1.8,SDEVICE-MIB::maxOutletAmps,Integer32,read-write,,current,,Maximum current per outlet in A; should last at least [stpkdr] MilliSeconds before triggering an alert.
.1.3.6.1.4.1.31034.2.10.1.9,SDEVICE-MIB::outputCTratio,Integer32,read-write,,current,,The multiplier to use in case of use of /5 current transformers. Defaults to 1.
.1.3.6.1.4.1.31034.2.11,SDEVICE-MIB::switchedoutletsTable,,not-accessible,,current,,This table contains the current status of switchable DEVICE's.
.1.3.6.1.4.1.31034.2.11.1,SDEVICE-MIB::switchedoutletsEntry,,not-accessible,channelIndex5,current,,The record containing the registers for the channel selected by channelIndex.
.1.3.6.1.4.1.31034.2.11.1.1,SDEVICE-MIB::channelIndex5,Integer32,not-accessible,,current,,The channel. Its value ranges between 1 and 48, depending on the number of channels, usually 1.
.1.3.6.1.4.1.31034.2.11.1.2,SDEVICE-MIB::currentState,Integer32,read-write,,current,,The actual state of the outlet relays. The hardware will contain max 48 outlets. Writing is only effective after setting [swounl].
.1.3.6.1.4.1.31034.2.11.1.3,SDEVICE-MIB::scheduled,Integer32,read-only,,current,,A one indicates pending activity; the switch delay has not yet expired.
.1.3.6.1.4.1.31034.2.11.1.4,SDEVICE-MIB::unlock,Integer32,read-write,,current,,Setting the value to one will release the safety for this outlet for a couple seconds; switching and rebooting are then temporarily enabled.
.1.3.6.1.4.1.31034.2.11.1.5,SDEVICE-MIB::individualOutletDelay,Integer32,read-write,,current,,Delay before an individual outlet switches on at power-up in Seconds.
.1.3.6.1.4.1.31034.2.12,SDEVICE-MIB::sensorTable,,not-accessible,,current,,This table contains the environmental measurements. As well internal temperature as external temperature probes.
.1.3.6.1.4.1.31034.2.12.1,SDEVICE-MIB::sensorEntry,,not-accessible,channelIndex8,current,,The record containing the registers for the channel selected by channelIndex.
.1.3.6.1.4.1.31034.2.12.1.1,SDEVICE-MIB::channelIndex8,Integer32,not-accessible,,current,,The channel. Its value ranges between 1 and 48, depending on the number of channels, usually 1.
.1.3.6.1.4.1.31034.2.12.1.2,SDEVICE-MIB::sensorType,OCTET,read-only,,current,,Type of connected sensor, either T, H or I for respectively Temperature (C), Humidity (%) or dry switch contact
.1.3.6.1.4.1.31034.2.12.1.3,SDEVICE-MIB::sensorValue,Integer32,read-only,,current,,Value of connected sensor
.1.3.6.1.4.1.31034.2.12.1.4,SDEVICE-MIB::sensorName,OCTET,read-write,,current,,User definable name for sensors.
.1.3.6.1.4.1.31034.11,SCHLEIFENBAUER-SMI::schleifenbauerProducts,,,,,,schleifenbauerProducts is the root OBJECT IDENTIFIER from which sysObjectId values are assigned. Acutal values are defined in  SCHLEIFENBAUER-PRODUCTS-MIB.
.1.3.6.1.4.1.31034.11.1,SCHLEIFENBAUER-PRODUCTS-MIB::hpdu,,,,,,
.1.3.6.1.4.1.31034.11.2,SCHLEIFENBAUER-PRODUCTS-MIB::dpm3,,,,,,
.1.3.6.1.4.1.31034.12,SCHLEIFENBAUER-SMI::schleifenbauerMgmt,,,,,,schleifenbauerMgmt is the main subtree for new mib development.
.1.3.6.1.4.1.31034.12.1,SCHLEIFENBAUER-DATABUS-MIB::schleifenbauerDatabusMIB,,,,,,This MIB describes the SNMP functions of network enabled databus devices. Copyright (c) 2016 by Schleifenbauer Holding BV 
.1.3.6.1.4.1.31034.12.1.0,SCHLEIFENBAUER-DATABUS-MIB::sdbMIBNotifications,,,,,,
.1.3.6.1.4.1.31034.12.1.0.1,SCHLEIFENBAUER-DATABUS-MIB::sdbDevSsDeviceStatusCodeChanged,,,,,,Device status code changed. OBJECTS { sdbDevSsDeviceStatusCode }
.1.3.6.1.4.1.31034.12.1.0.2,SCHLEIFENBAUER-DATABUS-MIB::sdbDevSsTemperatureAlertDetected,,,,,,Temperature alert detected. Internal temperature alert: OBJECTS { sdbDevSsTemperatureAlert, sdbDevMsIntTemperature, sdbDevMsIntTemperaturePeak } External analog temperature alert: OBJECTS { sdbDevSsTemperatureAlert, sdbDevMsExtTemperature, sdbDevMsExtTemperaturePeak } External digital temperature alert: OBJECTS { sdbDevSsTemperatureAlert, sdbDevSnsValue }
.1.3.6.1.4.1.31034.12.1.0.3,SCHLEIFENBAUER-DATABUS-MIB::sdbDevSsInputCurrentAlertDetected,,,,,,Input current alert detected. OBJECTS { sdbDevSsInputCurrentAlert, sdbDevInActualCurrent }
.1.3.6.1.4.1.31034.12.1.0.4,SCHLEIFENBAUER-DATABUS-MIB::sdbDevSsOutletCurrentAlertDetected,,,,,,Outlet current alert detected. OBJECTS { sdbDevSsOutletCurrentAlert, sdbDevOutMtActualCurrent }
.1.3.6.1.4.1.31034.12.1.0.5,SCHLEIFENBAUER-DATABUS-MIB::sdbDevSsInputVoltageAlertDetected,,,,,,Input voltage alert detected. OBJECTS { sdbDevSsInputVoltageAlert, sdbDevInActualVoltage }
.1.3.6.1.4.1.31034.12.1.0.6,SCHLEIFENBAUER-DATABUS-MIB::sdbDevSsOutletCurrentDropAlertDetected,,,,,,Outlet current drop alert detected. OBJECTS { sdbDevSsOutletCurrentDropAlert, sdbDevOutMtActualCurrent }
.1.3.6.1.4.1.31034.12.1.0.7,SCHLEIFENBAUER-DATABUS-MIB::sdbDevSsInputCurrentDropAlertDetected,,,,,,Input current drop alert detected. OBJECTS { sdbDevSsInputCurrentDropAlert, sdbDevInActualCurrent }
.1.3.6.1.4.1.31034.12.1.0.8,SCHLEIFENBAUER-DATABUS-MIB::sdbDevSsSensorChangeAlertDetected,,,,,,Sensor channel change alert detected. OBJECTS { sdbDevSsSensorChangeAlert }
.1.3.6.1.4.1.31034.12.1.0.9,SCHLEIFENBAUER-DATABUS-MIB::sdbMgmtStsRingStateChanged,,,,,,Ring state changed.  Ring state changded to open: OBJECTS { sdbMgmtStsRingState, sdbMgmtStsRingBreachIndex }  Ring state changded to closed: OBJECTS { sdbMgmtStsRingState }
.1.3.6.1.4.1.31034.12.1.0.10,SCHLEIFENBAUER-DATABUS-MIB::sdbDevSsOutletVoltageDropAlertDetected,,,,,,Outlet voltage drop alert detected. OBJECTS { sdbDevSsOutletVoltageDropAlert, sdbDevOutMtActualVoltage }
.1.3.6.1.4.1.31034.12.1.1,SCHLEIFENBAUER-DATABUS-MIB::sdbMIBObjects,,,,,,
.1.3.6.1.4.1.31034.12.1.1.1,SCHLEIFENBAUER-DATABUS-MIB::sdbMgmt,,,,,,
.1.3.6.1.4.1.31034.12.1.1.1.1,SCHLEIFENBAUER-DATABUS-MIB::sdbMgmtStatus,,,,,,
.1.3.6.1.4.1.31034.12.1.1.1.1.1,SCHLEIFENBAUER-DATABUS-MIB::sdbMgmtStsDevices,Integer32,read-only,,current,,The number of devices on the databus.
.1.3.6.1.4.1.31034.12.1.1.1.1.2,SCHLEIFENBAUER-DATABUS-MIB::sdbMgmtStsAddressableDevices,Integer32,read-only,,current,,The number of devices on the databus addressable by snmp.
.1.3.6.1.4.1.31034.12.1.1.1.1.3,SCHLEIFENBAUER-DATABUS-MIB::sdbMgmtStsNewDevices,Integer32,read-only,,current,,The number of new devices on the databus.
.1.3.6.1.4.1.31034.12.1.1.1.1.4,SCHLEIFENBAUER-DATABUS-MIB::sdbMgmtStsDuplicateDevices,Integer32,read-only,,current,,The number of duplicate devices on the databus.
.1.3.6.1.4.1.31034.12.1.1.1.1.5,SCHLEIFENBAUER-DATABUS-MIB::sdbMgmtStsRingState,INTEGER,read-only,,current,open(0):closed(1),If the device is in a bridge-like mode, this will indicate the actual state of the databus.
.1.3.6.1.4.1.31034.12.1.1.1.1.6,SCHLEIFENBAUER-DATABUS-MIB::sdbMgmtStsRingBreachIndex,Integer32,read-only,,current,,Indicates the breach index if the current state of the data bus is open. If the data bus is closed this has no meaning.
.1.3.6.1.4.1.31034.12.1.1.1.2,SCHLEIFENBAUER-DATABUS-MIB::sdbMgmtControl,,,,,,
.1.3.6.1.4.1.31034.12.1.1.1.2.1,SCHLEIFENBAUER-DATABUS-MIB::sdbMgmtCtrlScan,INTEGER,read-write,,current,idle(0):scan(1),Perform a bus scan. To verify if scanning is completed the value of this object can be read. During the bus scan the value remains 1. When the bus scan completed the value will be 0.
.1.3.6.1.4.1.31034.12.1.1.1.2.2,SCHLEIFENBAUER-DATABUS-MIB::sdbMgmtCtrlRenumberAllFromN,Integer32,read-write,,current,,Renumber all devices on the databus. If set to 0 all units will be set to 0. If set to another value, all units will be numbered in sequence starting from the value set.
.1.3.6.1.4.1.31034.12.1.1.1.2.3,SCHLEIFENBAUER-DATABUS-MIB::sdbMgmtCtrlRenumberZeros,INTEGER,read-write,,current,idle(0):renumber(1),Renumber all devices on the databus having address 0. Renumbering will be done in sequence. The sequence starts with the highest address found on the databus.
.1.3.6.1.4.1.31034.12.1.1.1.2.4,SCHLEIFENBAUER-DATABUS-MIB::sdbMgmtCtrlDevicesTable,,not-accessible,,current,,A table containing information of devices connected to the databus. The number of entries is given by the value of sdbMgmtStsDevices.
.1.3.6.1.4.1.31034.12.1.1.1.2.4.1,SCHLEIFENBAUER-DATABUS-MIB::sdbMgmtCtrlDevicesEntry,,not-accessible,sdbMgmtCtrlDevIndex,current,,Information entry containing objects of a particular databus device.
.1.3.6.1.4.1.31034.12.1.1.1.2.4.1.1,SCHLEIFENBAUER-DATABUS-MIB::sdbMgmtCtrlDevIndex,Integer32,not-accessible,,current,,A unique value for each device. Its value ranges between 1 and the value of sdbMgmtStsDevices with a maximum of 255. The value for each device will remain constant until the next scan is performed.
.1.3.6.1.4.1.31034.12.1.1.1.2.4.1.2,SCHLEIFENBAUER-DATABUS-MIB::sdbMgmtCtrlDevUnitAddress,Integer32,read-write,,current,,User defined address. This will be used for addressing the device on the databus.
.1.3.6.1.4.1.31034.12.1.1.1.2.4.1.3,SCHLEIFENBAUER-DATABUS-MIB::sdbMgmtCtrlDevHardwareAddress,OCTET,read-only,,current,,Hardware serial number. This cannot be changed. It can be used as backup unit address. format as 3 unsigned ints separated by dashes: int - int - int
.1.3.6.1.4.1.31034.12.1.1.1.2.4.1.4,SCHLEIFENBAUER-DATABUS-MIB::sdbMgmtCtrlDevIsNew,INTEGER,read-only,,current,no(0):yes(1),Indication if the device is new on the databus.
.1.3.6.1.4.1.31034.12.1.1.1.2.4.1.5,SCHLEIFENBAUER-DATABUS-MIB::sdbMgmtCtrlDevIsDuplicate,INTEGER,read-only,,current,no(0):yes(1),Indication if the device is conflicting with another device on the databus.
.1.3.6.1.4.1.31034.12.1.1.2,SCHLEIFENBAUER-DATABUS-MIB::sdbDevice,,,,,,
.1.3.6.1.4.1.31034.12.1.1.2.1,SCHLEIFENBAUER-DATABUS-MIB::sdbDevIdentification,,,,,,
.1.3.6.1.4.1.31034.12.1.1.2.1.1,SCHLEIFENBAUER-DATABUS-MIB::sdbDevIdTable,,not-accessible,,current,,A table containing identification information of devices connected to the databus. The number of entries is given by the value of sdbMgmtStsAddressableDevices.
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1,SCHLEIFENBAUER-DATABUS-MIB::sdbDevIdEntry,,not-accessible,sdbDevIdIndex,current,,Information entry containing information objects of a particular databus device.
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.1,SCHLEIFENBAUER-DATABUS-MIB::sdbDevIdSPDMVersion,Integer32,read-only,,current,,Data model version.
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.2,SCHLEIFENBAUER-DATABUS-MIB::sdbDevIdFirmwareVersion,Integer32,read-only,,current,,The firmware revision number.
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.3,SCHLEIFENBAUER-DATABUS-MIB::sdbDevIdBuildNumber,OCTET,read-only,,current,,Date and time the firmware was built.
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.4,SCHLEIFENBAUER-DATABUS-MIB::sdbDevIdSalesOrderNumber,OCTET,read-only,,current,,SP sales order number.
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.5,SCHLEIFENBAUER-DATABUS-MIB::sdbDevIdProductId,OCTET,read-only,,current,,SP product id.
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.6,SCHLEIFENBAUER-DATABUS-MIB::sdbDevIdSerialNumber,OCTET,read-only,,current,,SP serial number.
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.7,SCHLEIFENBAUER-DATABUS-MIB::sdbDevIdHardwareAddress,OCTET,read-only,,current,,Hardware serial number. This can not be changed. It can be used as backup unit address. Format as 3 unsigned ints separated by dashes (-) e.g. 12345-54321-00000
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.8,SCHLEIFENBAUER-DATABUS-MIB::sdbDevIdMacAddress,OCTET,read-only,,current,,The MAC address. This can not be changed. It represents an 802 MAC address as if it were transmitted least significant bit first. Format as six groups of 2 hexadecimal digits separated by colons (:) e.g. D0:22:12:B0:00:00
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.9,SCHLEIFENBAUER-DATABUS-MIB::sdbDevIdUnitAddress,Integer32,read-write,,current,,User defined address. This will be used for addressing the device on the databus.
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.10,SCHLEIFENBAUER-DATABUS-MIB::sdbDevIdName,OCTET,read-write,,current,,User configurable device name or identifier.
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.11,SCHLEIFENBAUER-DATABUS-MIB::sdbDevIdLocation,OCTET,read-write,,current,,User configurable device location identifier.
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.12,SCHLEIFENBAUER-DATABUS-MIB::sdbDevIdVanityTag,OCTET,read-write,,current,,Characters to be displayed as vanity text in display.
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.13,SCHLEIFENBAUER-DATABUS-MIB::sdbDevIdIndex,Integer32,not-accessible,,current,,A unique value for each device. Its value represents the unit address of the device and is used to address individual devices in the tree. The value for each device will remain constant until the next scan is performed.
.1.3.6.1.4.1.31034.12.1.1.2.2,SCHLEIFENBAUER-DATABUS-MIB::sdbDevConfiguration,,,,,,
.1.3.6.1.4.1.31034.12.1.1.2.2.1,SCHLEIFENBAUER-DATABUS-MIB::sdbDevCfTable,,not-accessible,,current,,A table containing configuration information of devices connected to the databus. The number of entries is given by the value of sdbMgmtStsAddressableDevices.
.1.3.6.1.4.1.31034.12.1.1.2.2.1.1,SCHLEIFENBAUER-DATABUS-MIB::sdbDevCfEntry,,not-accessible,sdbDevIdIndex,current,,Configuration entry containing configuration objects of a particular databus device.
.1.3.6.1.4.1.31034.12.1.1.2.2.1.1.1,SCHLEIFENBAUER-DATABUS-MIB::sdbDevCfPhases,Integer32,read-only,,current,,Number of phases for input metering.
.1.3.6.1.4.1.31034.12.1.1.2.2.1.1.2,SCHLEIFENBAUER-DATABUS-MIB::sdbDevCfOutletsTotal,Integer32,read-only,,current,,Total number of outlets including hardwired without switch/metered modules.
.1.3.6.1.4.1.31034.12.1.1.2.2.1.1.3,SCHLEIFENBAUER-DATABUS-MIB::sdbDevCfOutletsSwitched,Integer32,read-only,,current,,Number of switched outlets. If outlet numbering is non-contiguous its the highest outlet number.
.1.3.6.1.4.1.31034.12.1.1.2.2.1.1.4,SCHLEIFENBAUER-DATABUS-MIB::sdbDevCfOutletsMetered,Integer32,read-only,,current,,Number of metered outlets. If outlet numbering is non-contiguous its the highest outlet number.
.1.3.6.1.4.1.31034.12.1.1.2.2.1.1.5,SCHLEIFENBAUER-DATABUS-MIB::sdbDevCfSensors,Integer32,read-only,,current,,The number sensors.
.1.3.6.1.4.1.31034.12.1.1.2.2.1.1.6,SCHLEIFENBAUER-DATABUS-MIB::sdbDevCfMaximumLoad,Integer32,read-only,,current,,Maximum rated load of device per phase
.1.3.6.1.4.1.31034.12.1.1.2.3,SCHLEIFENBAUER-DATABUS-MIB::sdbDevSystemStatus,,,,,,
.1.3.6.1.4.1.31034.12.1.1.2.3.1,SCHLEIFENBAUER-DATABUS-MIB::sdbDevSsTable,,not-accessible,,current,,A table containing system status information of devices connected to the databus. The number of entries is given by the value of sdbMgmtStsAddressableDevices.
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1,SCHLEIFENBAUER-DATABUS-MIB::sdbDevSsEntry,,not-accessible,sdbDevIdIndex,current,,System status entry containing system status objects of a particular databus device.
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1.1,SCHLEIFENBAUER-DATABUS-MIB::sdbDevSsDeviceStatusCode,Integer32,read-only,,current,,Returns an internal status or error code. A value of 0 means OK. If not 0 it can be any of the following codes. Multiple status codes can be active at the same time. The value will be the sum of the active status codes. 1 = alert flagged 2 = settings(s) initialized 4 = power-on reset 8 = external reset 16 = watchdog timer caused reset 32 = brownout detected 64 = controller error 128 = slave module was reset
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1.2,SCHLEIFENBAUER-DATABUS-MIB::sdbDevSsTemperatureAlert,Integer32,read-only,,current,,An alert has been raised due to temperature exceeding treshhold. 0 = no alert 1 = internal temperature sensor 2 = external temperature sensor
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1.3,SCHLEIFENBAUER-DATABUS-MIB::sdbDevSsInputCurrentAlert,Integer32,read-only,,current,,An alert has been raised due to current exceeding treshhold. The value indicates the exceeding phase. 0 = no alert.
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1.4,SCHLEIFENBAUER-DATABUS-MIB::sdbDevSsOutletCurrentAlert,Integer32,read-only,,current,,An alert has been raised due to current exceeding treshhold. The value indicates the exceeding outlet. 0 = no alert.
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1.5,SCHLEIFENBAUER-DATABUS-MIB::sdbDevSsInputVoltageAlert,Integer32,read-only,,current,,An alert has been raised due to a voltage dip. The value indicates the dipped phase. 0 = no alert.
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1.6,SCHLEIFENBAUER-DATABUS-MIB::sdbDevSsOutletCurrentDropAlert,Integer32,read-only,,current,,An alert has been raised due to the current of a metered outlet suddenly dropping to near zero, possibly indicating a blown fuse. The value indicates the dropped outlet. 0 = no alert.
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1.7,SCHLEIFENBAUER-DATABUS-MIB::sdbDevSsInputCurrentDropAlert,Integer32,read-only,,current,,An alert has been raised due to the current of a metered input suddenly dropping to near zero, possibly indicating a blown fuse. The value indicates the dropped phase. 0 = no alert.
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1.8,SCHLEIFENBAUER-DATABUS-MIB::sdbDevSsSensorChangeAlert,Integer32,read-only,,current,,An alert has been raised due to a change in the number of sensors. The value indicates the previous amount of sensors.
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1.9,SCHLEIFENBAUER-DATABUS-MIB::sdbDevSsOutletVoltageDropAlert,Integer32,read-only,,current,,An alert has been raised due to voltage drop on this outlet. The value indicates the first failed outlet.
.1.3.6.1.4.1.31034.12.1.1.2.4,SCHLEIFENBAUER-DATABUS-MIB::sdbDevReset,,,,,,
.1.3.6.1.4.1.31034.12.1.1.2.4.1,SCHLEIFENBAUER-DATABUS-MIB::sdbDevRsTable,,not-accessible,,current,,A table providing reset capabilities to devices connected to the databus. The number of entries is given by the value of sdbMgmtStsAddressableDevices.
.1.3.6.1.4.1.31034.12.1.1.2.4.1.1,SCHLEIFENBAUER-DATABUS-MIB::sdbDevRsEntry,,not-accessible,sdbDevIdIndex,current,,Reset entry providing reset objects of a particular databus device.
.1.3.6.1.4.1.31034.12.1.1.2.4.1.1.1,SCHLEIFENBAUER-DATABUS-MIB::sdbDevRsReboot,INTEGER,read-write,,current,idle(0):reboot(1),Warm reboot/reset of device controller. NOTE: this will have NO effect on outlet status!
.1.3.6.1.4.1.31034.12.1.1.2.4.1.1.2,SCHLEIFENBAUER-DATABUS-MIB::sdbDevRsResetAlerts,INTEGER,read-write,,current,idle(0):reset(1),Reset all alert signals and device status code.
.1.3.6.1.4.1.31034.12.1.1.2.4.1.1.3,SCHLEIFENBAUER-DATABUS-MIB::sdbDevRsZeroInputKWhSubtotal,INTEGER,read-write,,current,idle(0):zero(1),Reset of all input kWh subtotal counters to zero.
.1.3.6.1.4.1.31034.12.1.1.2.4.1.1.4,SCHLEIFENBAUER-DATABUS-MIB::sdbDevRsZeroOutletKWhSubtotal,INTEGER,read-write,,current,idle(0):zero(1),Reset of all outlet kWh subtotal counter to zero.
.1.3.6.1.4.1.31034.12.1.1.2.4.1.1.5,SCHLEIFENBAUER-DATABUS-MIB::sdbDevRsResetPeaksAndDips,INTEGER,read-write,,current,idle(0):reset(1),Reset all peak and dip values to zero.
.1.3.6.1.4.1.31034.12.1.1.2.5,SCHLEIFENBAUER-DATABUS-MIB::sdbDevSettings,,,,,,
.1.3.6.1.4.1.31034.12.1.1.2.5.1,SCHLEIFENBAUER-DATABUS-MIB::sdbDevStTable,,not-accessible,,current,,A table containing setting information of devices connected to the databus. The number of entries is given by the value of sdbMgmtStsAddressableDevices.
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1,SCHLEIFENBAUER-DATABUS-MIB::sdbDevStEntry,,not-accessible,sdbDevIdIndex,current,,Setting entry containing settings objects of a particular databus device.
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.2,SCHLEIFENBAUER-DATABUS-MIB::sdbDevStAutoResetAlerts,Integer32,read-write,,current,,Auto reset alerts configuration. If set to 0 the auto reset alerts feature is disabled. If set to a  value greater then 0, the auto reset alerts feature is enabled and alerts will get cleared after the configured amount of seconds since the last alert condition have passed.
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.3,SCHLEIFENBAUER-DATABUS-MIB::sdbDevStExtendedNames,INTEGER,read-write,,current,disabled(0):enabled(1),Use original or longer names for inputs, outlets and sensors.
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.4,SCHLEIFENBAUER-DATABUS-MIB::sdbDevStPeakDuration,Integer32,read-write,,current,,Amount of ms a current peak should last before an alert is raised.
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.5,SCHLEIFENBAUER-DATABUS-MIB::sdbDevStFixedOutletDelay,Integer32,read-write,,current,,Minimal delay between two successive relay switches in milliseconds. Minimal delay is 100 ms. Will always be respected!
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.6,SCHLEIFENBAUER-DATABUS-MIB::sdbDevStPowerSaverMode,Integer32,read-write,,current,,Set backlight on time in seconds. 0 keeps display always on. Note that keeping the backlight on may decrease luminosity over time.
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.7,SCHLEIFENBAUER-DATABUS-MIB::sdbDevStOutletPowerUpMode,INTEGER,read-write,,current,off(0):sameState(1):sameStateDelayed(2),Behaviour of outlets on power-up.
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.8,SCHLEIFENBAUER-DATABUS-MIB::sdbDevStMaximumTemperature,Integer32,read-write,,current,,Maximum temperature threshold An alert will be generated whenever the temperature is above this value. Zero means disabled.
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.9,SCHLEIFENBAUER-DATABUS-MIB::sdbDevStDisplayOrientation,INTEGER,read-write,,current,noDisplay(0):verticalDisplayOnTop(1):verticalDisplayUpsideDown(2):horizontalDisplayAtLeft(3):horizontalDisplayAtRight(4),Display orientation.
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.10,SCHLEIFENBAUER-DATABUS-MIB::sdbDevStLocalAlertReset,INTEGER,read-write,,current,notAllowed(0):allowed(1),Allow alerts to be reset locally on device by pushing one of the buttons.
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.11,SCHLEIFENBAUER-DATABUS-MIB::sdbDevStCurrentDropDetection,INTEGER,read-write,,current,off(0):inputsOnly(1):outletsOnly(2):inputsAndOutlets(3),Enables the current drop detection function.
.1.3.6.1.4.1.31034.12.1.1.2.6,SCHLEIFENBAUER-DATABUS-MIB::sdbDevInput,,,,,,
.1.3.6.1.4.1.31034.12.1.1.2.6.1,SCHLEIFENBAUER-DATABUS-MIB::sdbDevInTable,,not-accessible,,current,,A table containing information of inputs of devices connected to the databus.
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1,SCHLEIFENBAUER-DATABUS-MIB::sdbDevInEntry,,not-accessible,sdbDevIdIndex:sdbDevInIndex,current,,Inputs entry containing objects of an input of a particular databus device. Note that this table has two indexes. sdbDevIdIndex to identify a particular device and sdbDevInIndex to identify a particular input of the device identified by sdbDevIdIndex.
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.1,SCHLEIFENBAUER-DATABUS-MIB::sdbDevInIndex,Integer32,not-accessible,,current,,A unique value for each input. Its value ranges between 1 and the value of sdbDevCfPhases.
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.2,SCHLEIFENBAUER-DATABUS-MIB::sdbDevInKWhTotal,Integer32,read-only,,current,,Total kWh value of an input. This value can not be reset.
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.3,SCHLEIFENBAUER-DATABUS-MIB::sdbDevInKWhSubtotal,Integer32,read-only,,current,,Subtotal kWh value of an input. This value can be reset.
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.4,SCHLEIFENBAUER-DATABUS-MIB::sdbDevInPowerFactor,Integer32,read-only,,current,,Power factor of input. The power factor of an AC power system is defined as the ratio of the real or active power to the apparent power and is a number between 0 and 1. This value is expressed as a percentage between 0% and 100%.
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.5,SCHLEIFENBAUER-DATABUS-MIB::sdbDevInActualCurrent,Integer32,read-only,,current,,Actual apparent, RMS current.
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.6,SCHLEIFENBAUER-DATABUS-MIB::sdbDevInPeakCurrent,Integer32,read-only,,current,,Peak apparent, RMS current. Highest value since last reset of the alerts.
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.7,SCHLEIFENBAUER-DATABUS-MIB::sdbDevInActualVoltage,Integer32,read-only,,current,,The actual voltage.
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.8,SCHLEIFENBAUER-DATABUS-MIB::sdbDevInMinVoltage,Integer32,read-only,,current,,RMS voltage dip. Lowest value since reset of alerts.
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.9,SCHLEIFENBAUER-DATABUS-MIB::sdbDevInPowerVoltAmpere,Integer32,read-only,,current,,Calculated apparent power.
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.10,SCHLEIFENBAUER-DATABUS-MIB::sdbDevInPowerWatt,Integer32,read-only,,current,,Calculated real power.
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.11,SCHLEIFENBAUER-DATABUS-MIB::sdbDevInMaxAmps,Integer32,read-write,,current,,Maximum current per input phase. Should last at least sdbDevStPeakDuration ms before triggering an alert.
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.12,SCHLEIFENBAUER-DATABUS-MIB::sdbDevInCTRatio,Integer32,read-write,,current,,The multiplier to use for the input CTs.
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.13,SCHLEIFENBAUER-DATABUS-MIB::sdbDevInName,OCTET,read-write,,current,,User configurable naming of inputs or phases.
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.14,SCHLEIFENBAUER-DATABUS-MIB::sdbDevInZeroKWhSubtotal,INTEGER,read-write,,current,idle(0):zero(1),Reset input kWh subtotal counter of a single input to zero.
.1.3.6.1.4.1.31034.12.1.1.2.7,SCHLEIFENBAUER-DATABUS-MIB::sdbDevOutlet,,,,,,
.1.3.6.1.4.1.31034.12.1.1.2.7.1,SCHLEIFENBAUER-DATABUS-MIB::sdbDevOutTable,,not-accessible,,current,,A table containing information of outlets of devices connected to the databus.
.1.3.6.1.4.1.31034.12.1.1.2.7.1.1,SCHLEIFENBAUER-DATABUS-MIB::sdbDevOutEntry,,not-accessible,sdbDevIdIndex:sdbDevOutIndex,current,,Outlets entry containing objects of an outlet of a particular databus device. Note that this table has two indexes. sdbDevIdIndex to identify a particular device and sdbDevOutIndex to identify a particular outlet of the device identified by sdbDevIdIndex.
.1.3.6.1.4.1.31034.12.1.1.2.7.1.1.1,SCHLEIFENBAUER-DATABUS-MIB::sdbDevOutIndex,Integer32,not-accessible,,current,,A unique value for each outlet. Its value ranges between 1 and the value of sdbDevCfOutletsTotal.
.1.3.6.1.4.1.31034.12.1.1.2.7.1.1.2,SCHLEIFENBAUER-DATABUS-MIB::sdbDevOutName,OCTET,read-write,,current,,User configurable naming of individual outlets.
.1.3.6.1.4.1.31034.12.1.1.2.7.2,SCHLEIFENBAUER-DATABUS-MIB::sdbDevOutMtTable,,not-accessible,,current,,A table containing information of metered outlets of devices connected to the databus.
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1,SCHLEIFENBAUER-DATABUS-MIB::sdbDevOutMtEntry,,not-accessible,sdbDevIdIndex:sdbDevOutMtIndex,current,,Metered outlets entry containing objects of a metered outlet of a particular databus device. Note that this table has two indexes. sdbDevIdIndex to identify a particular device and sdbDevOutMtIndex to identify a particular outlet of the device identified by sdbDevIdIndex.
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.1,SCHLEIFENBAUER-DATABUS-MIB::sdbDevOutMtIndex,Integer32,not-accessible,,current,,A unique value for each outlet. Its value ranges between 1 and the value of sdbDevCfOutletsMetered.
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.2,SCHLEIFENBAUER-DATABUS-MIB::sdbDevOutMtKWhTotal,Integer32,read-only,,current,,Total kWh value of an outlet. This value can not be reset.
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.3,SCHLEIFENBAUER-DATABUS-MIB::sdbDevOutMtKWhSubtotal,Integer32,read-only,,current,,Subotal kWh value of an outlet. This value can be reset.
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.4,SCHLEIFENBAUER-DATABUS-MIB::sdbDevOutMtPowerFactor,Integer32,read-only,,current,,Power factor of outlet. The power factor of an AC power system is defined as the ratio of the real or active power to the apparent power and is a number between 0 and 1. This number is expressed as a percentage between 0% and 100%.
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.5,SCHLEIFENBAUER-DATABUS-MIB::sdbDevOutMtActualCurrent,Integer32,read-only,,current,,Actual apparent, RMS current.
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.6,SCHLEIFENBAUER-DATABUS-MIB::sdbDevOutMtPeakCurrent,Integer32,read-only,,current,,Peak apparent, RMS current. Highest value since last reset of the alerts.
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.7,SCHLEIFENBAUER-DATABUS-MIB::sdbDevOutMtActualVoltage,Integer32,read-only,,current,,Actual voltage on outlet.
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.8,SCHLEIFENBAUER-DATABUS-MIB::sdbDevOutMtMaxAmps,Integer32,read-write,,current,,Maximum current per outlet. Should last at least sdbDevStPeakDuration ms before triggering an alert.
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.9,SCHLEIFENBAUER-DATABUS-MIB::sdbDevOutMtCTRatio,Integer32,read-write,,current,,The multiplier to use for the outlet CTs.
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.10,SCHLEIFENBAUER-DATABUS-MIB::sdbDevOutMtPowerVoltAmpere,Integer32,read-only,,current,,Calculated apparent power.
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.11,SCHLEIFENBAUER-DATABUS-MIB::sdbDevOutMtPowerWatt,Integer32,read-only,,current,,Calculated real power.
.1.3.6.1.4.1.31034.12.1.1.2.7.3,SCHLEIFENBAUER-DATABUS-MIB::sdbDevOutSwTable,,not-accessible,,current,,A table containing information of switched outlets of devices connected to the databus.
.1.3.6.1.4.1.31034.12.1.1.2.7.3.1,SCHLEIFENBAUER-DATABUS-MIB::sdbDevOutSwEntry,,not-accessible,sdbDevIdIndex:sdbDevOutSwIndex,current,,Switched outlets entry containing objects of a switched outlet of a particular databus device. Note that this table has two indexes. sdbDevIdIndex to identify a particular device and sdbDevOutSwIndex to identify a particular outlet of the device identified by sdbDevIdIndex.
.1.3.6.1.4.1.31034.12.1.1.2.7.3.1.1,SCHLEIFENBAUER-DATABUS-MIB::sdbDevOutSwIndex,Integer32,not-accessible,,current,,A unique value for each outlet. Its value ranges between 1 and the value of sdbDevCfOutletsSwitched.
.1.3.6.1.4.1.31034.12.1.1.2.7.3.1.2,SCHLEIFENBAUER-DATABUS-MIB::sdbDevOutSwCurrentState,INTEGER,read-write,,current,off(0):on(1),The actual state of the outlet relay. Note that Writing is only effective after setting sdbDevOutSwUnlock.
.1.3.6.1.4.1.31034.12.1.1.2.7.3.1.3,SCHLEIFENBAUER-DATABUS-MIB::sdbDevOutSwScheduled,INTEGER,read-only,,current,idle(0):scheduled(1),A one indicates pending activity; the switch delay has not yet expired.
.1.3.6.1.4.1.31034.12.1.1.2.7.3.1.4,SCHLEIFENBAUER-DATABUS-MIB::sdbDevOutSwUnlock,INTEGER,read-write,,current,locked(0):unlocked(1),Switching and rebooting is unlocked for 10 seconds by writing a 1.
.1.3.6.1.4.1.31034.12.1.1.2.7.3.1.5,SCHLEIFENBAUER-DATABUS-MIB::sdbDevOutSwIndividualOutletDelay,Integer32,read-write,,current,,Delay before an individual outlet switches on at power-up.
.1.3.6.1.4.1.31034.12.1.1.2.7.3.1.6,SCHLEIFENBAUER-DATABUS-MIB::sdbDevOutSwReboot,INTEGER,read-write,,current,idle(0):reboot(1),Reboot outlet relay if current state is on and outlet is unlocked; The outlet will be turned on after 10 seconds.
.1.3.6.1.4.1.31034.12.1.1.2.8,SCHLEIFENBAUER-DATABUS-MIB::sdbDevSensor,,,,,,
.1.3.6.1.4.1.31034.12.1.1.2.8.1,SCHLEIFENBAUER-DATABUS-MIB::sdbDevMeasuresTable,,not-accessible,,current,,A table containing information of temperatures of devices connected to the databus.
.1.3.6.1.4.1.31034.12.1.1.2.8.1.1,SCHLEIFENBAUER-DATABUS-MIB::sdbDevMeasuresEntry,,not-accessible,sdbDevIdIndex,current,,Device measures entry containing temperature information objects of a particular databus device.
.1.3.6.1.4.1.31034.12.1.1.2.8.1.1.1,SCHLEIFENBAUER-DATABUS-MIB::sdbDevMsIntTemperature,Integer32,read-only,,current,,Actual internal device temperature in deg C
.1.3.6.1.4.1.31034.12.1.1.2.8.1.1.2,SCHLEIFENBAUER-DATABUS-MIB::sdbDevMsExtTemperature,Integer32,read-only,,current,,Actual external device temperature sensor in deg C.
.1.3.6.1.4.1.31034.12.1.1.2.8.1.1.3,SCHLEIFENBAUER-DATABUS-MIB::sdbDevMsIntTemperaturePeak,Integer32,read-only,,current,,Peak internal device temperature since last reset of alerts.
.1.3.6.1.4.1.31034.12.1.1.2.8.1.1.4,SCHLEIFENBAUER-DATABUS-MIB::sdbDevMsExtTemperaturePeak,Integer32,read-only,,current,,Peak external device temperature since last reset of alerts.
.1.3.6.1.4.1.31034.12.1.1.2.8.2,SCHLEIFENBAUER-DATABUS-MIB::sdbDevSnsTable,,not-accessible,,current,,A table containing information of sensors of devices connected to the databus.
.1.3.6.1.4.1.31034.12.1.1.2.8.2.1,SCHLEIFENBAUER-DATABUS-MIB::sdbDevSnsEntry,,not-accessible,sdbDevIdIndex:sdbDevSnsIndex,current,,Sensors entry containing objects of a sensor of a particular databus device. Note that this table has two indexes. sdbDevIdIndex to identify a particular device and sdbDevSnsIndex to identify a particular sensor of the device identified by sdbDevIdIndex.
.1.3.6.1.4.1.31034.12.1.1.2.8.2.1.1,SCHLEIFENBAUER-DATABUS-MIB::sdbDevSnsIndex,Integer32,not-accessible,,current,,A unique value for each sensor. Its value ranges between 1 and the value of sdbDevCfSensors.
.1.3.6.1.4.1.31034.12.1.1.2.8.2.1.2,SCHLEIFENBAUER-DATABUS-MIB::sdbDevSnsType,OCTET,read-only,,current,,Type of connected sensor. T = Temperature (C) H = Humidity (%) I = dry switch contact
.1.3.6.1.4.1.31034.12.1.1.2.8.2.1.3,SCHLEIFENBAUER-DATABUS-MIB::sdbDevSnsValue,Integer32,read-only,,current,,Value of connected sensor
.1.3.6.1.4.1.31034.12.1.1.2.8.2.1.4,SCHLEIFENBAUER-DATABUS-MIB::sdbDevSnsName,OCTET,read-write,,current,,User definable name for sensors.
.1.3.6.1.4.1.31034.12.1.2,SCHLEIFENBAUER-DATABUS-MIB::sdbMIBConformance,,,,,,
.1.3.6.1.4.1.31034.12.1.2.1,SCHLEIFENBAUER-DATABUS-MIB::sdbMIBCompliances,,,,,,
.1.3.6.1.4.1.31034.12.1.2.1.1,SCHLEIFENBAUER-DATABUS-MIB::sdbMIBCompliance,,,,,,The requirements for conformance to the SCHLEIFENBAUER-DATABUS-MIB.
.1.3.6.1.4.1.31034.12.1.2.2,SCHLEIFENBAUER-DATABUS-MIB::sdbMIBGroups,,,,,,
.1.3.6.1.4.1.31034.12.1.2.2.1,SCHLEIFENBAUER-DATABUS-MIB::sdbMIBNotificationGroup,,,,,,A collection of notifications.
.1.3.6.1.4.1.31034.12.1.2.2.3,SCHLEIFENBAUER-DATABUS-MIB::sdbMIBDevIdGroup,,,,,,A collection of objects providing identification information about the device.
.1.3.6.1.4.1.31034.12.1.2.2.4,SCHLEIFENBAUER-DATABUS-MIB::sdbMIBDevCfGroup,,,,,,A collection of objects providing configuration information about the device.
.1.3.6.1.4.1.31034.12.1.2.2.5,SCHLEIFENBAUER-DATABUS-MIB::sdbMIBDevSsGroup,,,,,,A collection of objects providing status information about the device.
.1.3.6.1.4.1.31034.12.1.2.2.6,SCHLEIFENBAUER-DATABUS-MIB::sdbMIBDevRsGroup,,,,,,Groups resettable attributes op the device.
.1.3.6.1.4.1.31034.12.1.2.2.7,SCHLEIFENBAUER-DATABUS-MIB::sdbMIBDevStGroup,,,,,,A collection of objects providing the actual settings about the device.
.1.3.6.1.4.1.31034.12.1.2.2.8,SCHLEIFENBAUER-DATABUS-MIB::sdbMIBDevInGroup,,,,,,A collection of objects providing the actual input measurements of the device.
.1.3.6.1.4.1.31034.12.1.2.2.9,SCHLEIFENBAUER-DATABUS-MIB::sdbMIBDevOutGroup,,,,,,A collection of objects providing the actual outlet measurements of the device.
.1.3.6.1.4.1.31034.12.1.2.2.10,SCHLEIFENBAUER-DATABUS-MIB::sdbMIBDevOutMtGroup,,,,,,A collection of objects providing the actual outlet measurements of the device.
.1.3.6.1.4.1.31034.12.1.2.2.11,SCHLEIFENBAUER-DATABUS-MIB::sdbMIBDevOutSwGroup,,,,,,A collection of objects providing the actual outlet measurements of the device.
.1.3.6.1.4.1.31034.12.1.2.2.12,SCHLEIFENBAUER-DATABUS-MIB::sdbMIBDevSensorGroup,,,,,,A collection of objects providing the actual environmental measurements of the device.
.1.3.6.1.4.1.31034.12.1.2.2.13,SCHLEIFENBAUER-DATABUS-MIB::sdbMIBMgmtStatusGroup,,,,,,A collection of objects providing management status information about the databus.
.1.3.6.1.4.1.31034.12.1.2.2.14,SCHLEIFENBAUER-DATABUS-MIB::sdbMIBMgmtControlGroup,,,,,,A collection of objects providing management control information about the databus.
.1.3.6.1.4.1.31034.13,SCHLEIFENBAUER-SMI::schleifenbauerModules,,,,,,schleifenbauerModules provides a root object identifier from which MODULE-IDENTITY values may be assigned.
.1.3.6.1.4.1.31034.13.2,SCHLEIFENBAUER-PRODUCTS-MIB::schleifenbauerProductsMIB,,,,,,TODO: description.  Copyright (c) 2015 by Schleifenbauer Products BV 
.1.3.6.1.4.1.31034.99,SDEVICE-MIB::conformance,,,,,,
.1.3.6.1.4.1.31034.99.1,SDEVICE-MIB::compliances,,,,,,
.1.3.6.1.4.1.31034.99.1.1,SDEVICE-MIB::compliance,,,,,,The requirements for conformance to the SPGW-MIB.
.1.3.6.1.4.1.31034.99.2,SDEVICE-MIB::groups,,,,,,
.1.3.6.1.4.1.31034.99.2.1,SDEVICE-MIB::identificationGroup,,,,,,A collection of objects providing identification information about the device.
.1.3.6.1.4.1.31034.99.2.2,SDEVICE-MIB::configurationGroup,,,,,,A collection of objects providing configuration information about the device.
.1.3.6.1.4.1.31034.99.2.3,SDEVICE-MIB::systemStatusGroup,,,,,,A collection of objects providing status information about the device.
.1.3.6.1.4.1.31034.99.2.4,SDEVICE-MIB::resetGroup,,,,,,Groups resettable attributes op the device.
.1.3.6.1.4.1.31034.99.2.5,SDEVICE-MIB::settingsGroup,,,,,,A collection of objects providing the actual settings about the device.
.1.3.6.1.4.1.31034.99.2.6,SDEVICE-MIB::switchedOutletsGroup,,,,,,A collection of objects providing the actual outlet status of the device.
.1.3.6.1.4.1.31034.99.2.7,SDEVICE-MIB::inputMeasuresGroup,,,,,,A collection of objects providing the actual input measurements of the device.
.1.3.6.1.4.1.31034.99.2.8,SDEVICE-MIB::outputMeasuresGroup,,,,,,A collection of objects providing the actual output measurements of the device.
.1.3.6.1.4.1.31034.99.2.9,SDEVICE-MIB::sensorsGroup,,,,,,A collection of objects providing the actual environmental measurements of the device.
.1.3.6.1.5,SNMPv2-SMI::security,,,,,,
.1.3.6.1.6,SNMPv2-SMI::snmpV2,,,,,,
.1.3.6.1.6.1,SNMPv2-SMI::snmpDomains,,,,,,
.1.3.6.1.6.2,SNMPv2-SMI::snmpProxys,,,,,,
.1.3.6.1.6.3,SNMPv2-SMI::snmpModules,,,,,,